Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38603618

RESUMO

OBJECTIVES: Recurrence of tricuspid regurgitation (TR) after tricuspid annuloplasty can occur in cases where a dilated right ventricle exists and subsequent leaflet tethering follows. We previously reported a new technique of the right ventricular papillary muscle approximation (RV-PMA) for functional TR associated with leaflet tethering. The objective of this study is to elucidate the mid-term outcomes and evaluate the durability of RV-PMA. METHODS: Between January 2014 and March 2023, we applied RV-PMA in 20 patients of advanced functional TR with severe leaflet tethering. The indication of the technique was severe TR with leaflet tethering height >8 mm, and/or a right ventricular end-diastolic diameter >45 mm. The patients were followed up with echocardiography before discharge and at annual interval thereafter. RESULTS: There was no perioperative mortality. In the echocardiography performed before discharge, TR was decreased to mild or less in 85%, and a significant improvement in right ventricular end-diastolic diameter and tethering height were achieved (53-45 mm and 11.1-4.4 mm, respectively). Furthermore, during the median 3-year follow-up period, TR was kept controlled mild or less in 80% of the cases. CONCLUSIONS: RV-PMA is considered to be a safe, effective and durable technique as an additional approach for tricuspid annuloplasty.


Assuntos
Ventrículos do Coração , Músculos Papilares , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Músculos Papilares/cirurgia , Músculos Papilares/diagnóstico por imagem , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Ventrículos do Coração/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Resultado do Tratamento , Ecocardiografia , Anuloplastia da Valva Cardíaca/métodos , Estudos Retrospectivos , Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Índice de Gravidade de Doença , Seguimentos
2.
Kyobu Geka ; 75(10): 791-795, 2022 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-36155571

RESUMO

Left ventricular free wall rupture( LVFWR) is a potentially fatal complication after acute myocardial infarction (AMI). Its onset is often unpredictable and circulatory collapse develops abruptly. When cardiac tamponade is detected after AMI, pericardial drainage should be performed promptly. If percutaneous drainage is ineffective, surgical drainage should be performed without hesitation. Veno-arterial extracorporeal oxygenation (VA-ECMO) cannot necessarily provide effective brain protection because of elevated venous pressure. Although suture-less repair often results in sufficient hemostasis, recurrent rupture sometimes develops. If any type of LVFWR is suspected, immediate surgical intervention can save lives.


Assuntos
Tamponamento Cardíaco , Ruptura Cardíaca , Infarto do Miocárdio , Tamponamento Cardíaco/etiologia , Ruptura Cardíaca/etiologia , Ruptura Cardíaca/cirurgia , Humanos , Infarto do Miocárdio/complicações
3.
JMIR Form Res ; 6(8): e35396, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35916709

RESUMO

BACKGROUND: Some attempts have been made to detect atrial fibrillation (AF) with a wearable device equipped with photoelectric volumetric pulse wave technology, and it is expected to be applied under real clinical conditions. OBJECTIVE: This study is the second part of a 2-phase study aimed at developing a method for immediate detection of paroxysmal AF, using a wearable device with built-in photoplethysmography (PPG). The objective of this study is to develop an algorithm to immediately diagnose AF by an Apple Watch equipped with a PPG sensor that is worn by patients undergoing cardiac surgery and to use machine learning on the pulse data output from the device. METHODS: A total of 80 patients who underwent cardiac surgery at a single institution between June 2020 and March 2021 were monitored for postoperative AF, using a telemetry-monitored electrocardiogram (ECG) and an Apple Watch. AF was diagnosed by qualified physicians from telemetry-monitored ECGs and 12-lead ECGs; a diagnostic algorithm was developed using machine learning on the pulse rate data output from the Apple Watch. RESULTS: One of the 80 patients was excluded from the analysis due to redness caused by wearing the Apple Watch. Of 79 patients, 27 (34.2%) developed AF, and 199 events of AF including brief AF were observed. Of them, 18 events of AF lasting longer than 1 hour were observed, and cross-correlation analysis showed that pulse rate measured by Apple Watch was strongly correlated (cross-correlation functions [CCF]: 0.6-0.8) with 8 events and very strongly correlated (CCF>0.8) with 3 events. The diagnostic accuracy by machine learning was 0.9416 (sensitivity 0.909 and specificity 0.838 at the point closest to the top left) for the area under the receiver operating characteristic curve. CONCLUSIONS: We were able to safely monitor pulse rate in patients who wore an Apple Watch after cardiac surgery. Although the pulse rate measured by the PPG sensor does not follow the heart rate recorded by telemetry-monitored ECGs in some parts, which may reduce the accuracy of AF diagnosis by machine learning, we have shown the possibility of clinical application of using only the pulse rate collected by the PPG sensor for the early detection of AF.

4.
JMIR Cardio ; 4(1): e14857, 2020 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-32012044

RESUMO

BACKGROUND: Wearable devices with photoplethysmography (PPG) technology can be useful for detecting paroxysmal atrial fibrillation (AF), which often goes uncaptured despite being a leading cause of stroke. OBJECTIVE: This study is the first part of a 2-phase study that aimed at developing a method for immediate detection of paroxysmal AF using PPG-integrated wearable devices. In this study, the diagnostic performance of 2 major smart watches, Apple Watch Series 3 and Fitbit (FBT) Charge HR Wireless Activity Wristband, each equipped with a PPG sensor, was compared, and the pulse rate data outputted from those devices were analyzed for precision and accuracy in reference to the heart rate data from electrocardiography (ECG) during AF. METHODS: A total of 40 subjects from patients who underwent cardiac surgery at a single center between September 2017 and March 2018 were monitored for postoperative AF using telemetric ECG and PPG devices. AF was diagnosed using a 12-lead ECG by qualified physicians. Each subject was given a pair of smart watches, Apple Watch and FBT, for simultaneous pulse rate monitoring. The heart rate of all subjects was also recorded on the telemetry system. Time series pulse rate trends and heart rate trends were created and analyzed for trend pattern similarities. Those trend data were then used to determine the accuracy of PPG-based pulse rate measurements in reference to ECG-based heart rate measurements during AF. RESULTS: Of the 20 AF events in group FBT, 6 (30%) showed a moderate or higher correlation (cross-correlation function>0.40) between pulse rate trend patterns and heart rate trend patterns. Of the 16 AF events in group Apple Watch (workout [W] mode), 12 (75%) showed a moderate or higher correlation between the 2 trend patterns. Linear regression analyses also showed a significant correlation between the pulse rates and the heart rates during AF in the subjects with Apple Watch. This correlation was not observed with FBT. The regression formula for Apple Watch W mode and FBT was X=14.203 + 0.841Y and X=58.225 + 0.228Y, respectively (where X denotes the mean of all average pulse rates during AF and Y denotes the mean of all corresponding average heart rates during AF), and the coefficient of determination (R2) was 0.685 and 0.057, respectively (P<.001 and .29, respectively). CONCLUSIONS: In this validation study, the detection precision of AF and measurement accuracy during AF were both better with Apple Watch W mode than with FBT.

5.
J Artif Organs ; 23(3): 270-274, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31897739

RESUMO

Left ventricular assist device (LVAD) is an established therapy for patients with severe heart failure. Because the incidence of cardiotoxicity owing to anticancer agents is low, it is difficult to predict the recovery prospects when the cause of heart failure is due to anticancer agents. In this context, cancer patients who present with severe symptoms of heart failure and who fail medical therapy for heart failure may pose a dilemma, especially in countries such as Japan where implantable LVADs are not approved for purposes other than bridging to transplant. Recently, we encountered a 32-year-old woman with chemotherapy-related cardiomyopathy that developed after anticancer treatment using trastuzumab and anthracycline. LVAD therapy was the only option to save the young woman. The patient received an extracorporeal LVAD, her cardiac function gradually recovered while on support, and the device was successfully removed.


Assuntos
Antraciclinas/efeitos adversos , Antineoplásicos/efeitos adversos , Insuficiência Cardíaca/induzido quimicamente , Insuficiência Cardíaca/terapia , Coração Auxiliar , Trastuzumab/efeitos adversos , Adulto , Feminino , Humanos , Leucemia Mieloide Aguda/tratamento farmacológico
6.
Heart Vessels ; 33(1): 1-8, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28744572

RESUMO

The purpose of this study is to compare the late outcome of aortic valve replacement with or without preoperative coronary artery disease, and with or without coronary artery bypass. Between 2014 and 2015, 291 patients underwent aortic valve replacement. Average follow-up term was 2.5 ± 2.2 years. The retrospective comparative study was performed between the patients with (n = 115) or without (n = 176) preoperative coronary artery disease (Study 1) and with (n = 93) or without (n = 198) coronary artery bypass grafting (Study 2). Study 1: male patients were more, and diabetes was more in the patients with coronary artery disease. Long-term survival rate was significantly low in the patients with coronary artery disease (p = 0.0002 by log rank test). Freedom from repeat coronary revascularization rate was lower in the patients with coronary artery disease (p = 0.02 by log rank test). Study 2: operation time (419 ± 130 vs 290 ± 101; p = 0.0001) was longer in the patients with coronary artery bypass grafting. Improvement of ejection fraction at follow-up was more in the patients with coronary artery bypass(114 ± 43 vs 104 ± 26%; p = 0.03). Long-term survival rate and freedom from major adverse cardiac event rater were not different with or without coronary artery bypass grafting (p = 0.26 and p = 0.59, respectively, by log rank test). Although prevalence of coronary artery disease inversely affected the long-term outcome of the aortic valve replacement, simultaneous coronary artery bypass did not. Aggressive simultaneous coronary revascularization would be important to improve the long-term outcome of aortic valve replacement.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Ponte de Artéria Coronária , Doença da Artéria Coronariana/complicações , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Feminino , Seguimentos , Humanos , Japão/epidemiologia , Masculino , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo
7.
J Am Chem Soc ; 135(37): 13684-7, 2013 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-24001124

RESUMO

A straightforward synthesis of ecteinascidin 743 was accomplished from readily available l-glutamic acid as a single chiral source. Our novel synthesis features a concise and convergent approach for construction of the B-ring, consisting of a sequence involving a stereoselective Heck reaction between a diazonium salt and an enamide, oxidative cleavage of the resulting alkene, and intramolecular ortho substitution of the phenol by an aldehyde.


Assuntos
Antineoplásicos/síntese química , Dioxóis/síntese química , Descoberta de Drogas , Tetra-Hidroisoquinolinas/síntese química , Antineoplásicos/química , Dioxóis/química , Estrutura Molecular , Tetra-Hidroisoquinolinas/química , Trabectedina
8.
J Am Chem Soc ; 131(18): 6624-31, 2009 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-19378963

RESUMO

Cyanoformate esters add across 1,2-dienes in the presence of a nickel/PMe(2)Ph catalyst to afford beta-cyano-alpha-methylenealkanoates regioselectively, which are kinetically favored and readily isomerize to thermodynamically favored alpha-cyanomethyl-alpha,beta-unsaturated carboxylates at high temperature under the nickel catalysis, possibly through oxidative addition of the C-CN bond. Similar cyanoesterification products are produced from chloroformate esters, trimethylsilyl cyanide, and 1,2-dienes in the presence of a nickel/dppp catalyst. The resulting cyanoesterification products have a structure of allylic cyanide and thus undergo further allyl cyanation reaction across alkynes with the aid of a nickel/P(4-CF(3)-C(6)H(4))(3) catalyst to afford highly substituted acrylonitrile derivatives.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA